Platform Instrumentation

Below is a list of currently available instrumentation at the platform divided into the four main categories. Click to expand menu.
Organic GC-MS

• GC-MSD (Agilent 5975)
A simple quadrupole MS for routine analysis of target compounds that require moderate (ppt) sensitivity (liquid injections; ionization: EI, CI or ECNI).

• GC-TOF-HRMS (Leco GC-HRT)
An instrument with very high resolution, excellent mass accuracy (1 ppm) and good sensitivity (ppt) well suited for automated analyses and identification of unknowns (liquid injections or thermal desorption; ionization: EI and CI).

• GC×GC-QTOF-HRMS (Agilent 7250)
An instrument with very high peak capacity, high resolution, excellent mass accuracy (<2 ppm) and high sensitivity (ppq-ppt), and well suited for identification of unknowns (liquid injections; ionization: EI, CI and ECNI).

Organic LC-MS

• LC-TSQ-MS/MS (Thermo Quantiva)
A state-of-the-art triple-quad MS with on-line SPE capabilities for routine target analysis at ppt-levels (liquid injections; ionization: ESI, HESI or APCI/PI).

• LC-IMS-MS/MS (Agilent 6560)
A very sensitive (ppt) instrument with high mass accuracy (1 ppm) and on-line SPE and 2D separation capabilities. It is well suited for suspect and non-target analysis as well as multi-residue target analysis (liquid injections; ionization: ESI or APCI).

Organo-Metal ICP-MS

• LC-ICP-tqMS (Agilent 8900 ICP-MS Triple Quad)
An LC-ICPMS for trace element analysis. LC compatible metal compounds can be determined down to fmol amounts.

• TD-GC-ICP-qMS (Agilent 7700 ICP-MS Quad)
A thermal desorption GC-ICP-MS system for trace metal compound analysis. GC compatible metal compounds can be determined down to fmol amounts.

• ICP-qMS (Agilent 7500a)
An ICP-MS for analysis of trace element compounds. GC compatible metal compounds can be determined down to fmol amounts.

Isotopic Ratio MS
  •  TR-MIMS (Thermo DELTA V Plus)
    A Time-resolved membrane-inlet isotopic ratio mass spectrometer, used for assays of gaseous analytes . Its connectability to various membrane-inlet sample chambers enables time-resolved monitoring of gaseous products and their iso-topologues.

 

Instrument list, detailed. Click to expand.
Producer
Model
MS type
Chromatographya
Ionizationb
Analyzerc
Resolution / mass accuracy
Year
Contact (090-786XXXX)
Agilent 7700 Atomic GC ICP Q 0.3 amu 2009 Erik Björn (5198)
Thermo Delta V Plus Isotope ratio Time resolved MIMS EI Sector (B) 9 collectors Dmitry Shevela (5293)
Agilent 5975 Molecular GC EI, Q unit mass 2005 Per Liljelind (9321)
Thermo Quantiva Molecular LC, SPE-LC ESI, APCI/PI QQQ 0.2 amu 2015 Richard Lindberg (5464)
Agilent 7250 Molecular GC, GCxGC EI, +CI, -CI Q-TOF 12,000 / 3 ppm 2015 Peter (6667)
aFront-end system bIonization techniques   cAnalyzer type
GC: Gas Chromatography AP: Athmosperic Pressure
GCxGC: 2D GC CI: Chemical Ionization
Flash-GC: Rapid GC EI: Electron Impact Ionization
LC: Liquid Chromatography ESI: Electrospray Ionization Q: Quadrupole
LCxLC: 2D LC ICP: Inductively Coupled Plasma TOF: Time-of-flight
SPE: Solid Phase Extraction PI: Photo Ionization
MIMS: Membrane Inlet MS
Instrument list, detailed. Click to expand.
Producer
Model
MS type
Chromatographya
Ionizationb
Analyzerc
Resolution / mass accuracy
Year
Contact (090-786XXXX)
Agilent 7700 Atomic GC ICP Q 0.3 amu 2009 Erik Björn (5198)
PE Sciex ELAN 6600 Atomic LC ICP Q 0.3 amu   Erik Björn (5198)
PE Sciex ELAN DRC-e Atomic LC ICP Q 0.3 amu   Erik Björn (5198)
                 
Thermo Delta V Plus Isotope ratio Time resolved MIMS EI Sector (B) 9 collectors   Dmitry Shevela (5293)
                 
Agilent 5975 Molecular GC EI, +CI, -CI Q unit mass 2005 Per Liljelind (9321)
Leco Pegasus 4D Molecular GC, GCxGC EI TOF unit mass 2002 Peter Haglund (6667)
Leco GC-HRT Molecular GC, flush-GC EI, +CI TOF 50,000 / 1 ppm 2012 Peter Haglund (6667)
Waters Autospec Ultima Molecular GC EI, +CI, -CI Sector (EBE) 50,000 / 1-3 ppm 2006 Per Liljelind (9321)
Waters Autospec Ultima Molecular GC EI, +CI, -CI Sector (EBE) 50,000 / 1-3 ppm   Per Liljelind (9321)

Agilent

6560 Molecular (SPE-)LC, LCxLC, GC ESI, APCI IMS-Q-TOF 40000 / 1 ppm 2015 Peter Haglund (6667)
Thermo Quantiva Molecular LC, SPE-LC ESI, APCI/PI QQQ 0.2 amu 2015 Richard Lindberg (5464)
Thermo LCQ Fleet Molecular LC ESI, APCI/PI QQQ 0.3 amu 2008 Richard Lindberg (5464)
Thermo Quantum Ultra Molecular LC, SPE-LC ESI, APCI/PI QQQ 0.2 amu 2007 Richard Lindberg (5464)
Agilent 7500a + 7200B Atomic/Mol GC, GCxGC ICP Quad unit mass 2000 Erik/Peter (5198, 6667)
Agilent 7500a + 7200B Atomic/Mol GC, GCxGC EI, +CI, -CI Q-TOF 12,000 / 3 ppm 2015 Erik/Peter (5198, 6667)
                 
  aFront-end system   bIonization techniques   cAnalyzer type      
  GC: Gas Chromatography  AP: Athmosperic Pressure  B: Magnetic sector     
  GCxGC: 2D GC   CI: Chemical Ionization   E: Electrostatic sector    
  Flash-GC: Rapid GC   EI: Electron Impact Ionization   IMS: Ion mobility spectrometry    
  LC: Liquid Chromatography ESI: Electrospray Ionization Q: Quadrupole      
  LCxLC: 2D LC   ICP: Inductively Coupled Plasma TOF: Time-of-flight    
  SPE: Solid Phase Extraction PI: Photo Ionization          
    MIMS: Membrane Inlet MS         
Instrument list, detailed. Click to expand.
Producer
Model
MS type
Chromatographya
Ionizationb
Analyzerc
Resolution / mass accuracy
Year
Contact (090-786XXXX)
Agilent 7700 Atomic GC ICP Q 0.3 amu 2009 Erik Björn (5198)
PE Sciex ELAN 6600 Atomic LC ICP Q 0.3 amu Erik Björn (5198)
PE Sciex ELAN DRC-e Atomic LC ICP Q 0.3 amu Erik Björn (5198)
Thermo Delta V Plus Isotope ratio Time resolved MIMS EI Sector (B) 9 collectors Dmitry Shevela (5293)
Agilent 5975 Molecular GC EI, +CI, -CI Q unit mass 2005 Per Liljelind (9321)
Leco Pegasus 4D Molecular GC, GCxGC EI TOF unit mass 2002 Peter Haglund (6667)
Leco GC-HRT Molecular GC, flush-GC EI, +CI TOF 50,000 / 1 ppm 2012 Peter Haglund (6667)
Waters Autospec Ultima Molecular GC EI, +CI, -CI Sector (EBE) 50,000 / 1-3 ppm 2006 Per Liljelind (9321)
Waters Autospec Ultima Molecular GC EI, +CI, -CI Sector (EBE) 50,000 / 1-3 ppm Per Liljelind (9321)
Agilent 6560 Molecular (SPE-)LC, LCxLC, GC ESI, APCI IMS-Q-TOF 40000 / 1 ppm 2015 Peter Haglund (6667)
Thermo Quantiva Molecular LC, SPE-LC ESI, APCI/PI QQQ 0.2 amu 2015 Richard Lindberg (5464)
Thermo LCQ Fleet Molecular LC ESI, APCI/PI QQQ 0.3 amu 2008 Richard Lindberg (5464)
Thermo Quantum Ultra Molecular LC, SPE-LC ESI, APCI/PI QQQ 0.2 amu 2007 Richard Lindberg (5464)
Agilent 7500a + 7200B Atomic/Mol GC, GCxGC ICP Quad unit mass 2000 Erik/Peter (5198, 6667)
Agilent 7500a + 7200B Atomic/Mol GC, GCxGC EI, +CI, -CI Q-TOF 12,000 / 3 ppm 2015 Erik/Peter (5198, 6667)
aFront-end system bIonization techniques   cAnalyzer type
GC: Gas Chromatography AP: Athmosperic Pressure B: Magnetic sector
GCxGC: 2D GC CI: Chemical Ionization E: Electrostatic sector
Flash-GC: Rapid GC EI: Electron Impact Ionization IMS: Ion mobility spectrometry
LC: Liquid Chromatography ESI: Electrospray Ionization Q: Quadrupole
LCxLC: 2D LC ICP: Inductively Coupled Plasma TOF: Time-of-flight
SPE: Solid Phase Extraction PI: Photo Ionization
MIMS: Membrane Inlet MS